Brand Name : HongCe
Model Number : HVF-3A
Certification : TUV、ITS、CSA、BV、SGS 、CNAS(cost additional)
Place of Origin : China
MOQ : 1 set
Price : Negotiable
Payment Terms : T/T, L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability : 10 set per month
Delivery Time : 20 days
Packaging Details : Plywood
Standards : IEC60695, UL94,UL498,UL1363
Operation system : Mitsubishi PLC
Burning angle : 0°,20°,45°adjustable
Burning type : 50W&500W
Flowmeter : Matheson
50W 500W Mitsubishi PLC Plastic Vertical Horizontal Flammability Tester UL94 Fire Chamber
Products information:
HongTong's series of horizontal-vertical flame test apparatus are designed and manufactured according to UL94,IEC60695-11-2, IEC60695-11-3, IEC60695-11-4, IEC60695-11-20.
These flammability testers simulate the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. Mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method.
This 50W and 500W horizontal-vertical flame test equipment adopts the advanced Mitsubishi PLC intelligent control system, 7 inches touch screen, with humanized operation interface, and with remote wireless sensors operation so that record more precise; using integral intake ignition systems, the combustion time delays 0.1S, thus to make sure the sufficient time of gas burning.
The testers adopt to matte black background, multi-functional flame measure gauge to make the flame adjustment works easier, box full of stainless steel, large observation window, imported fire control systems, nice appearance. And they are gathering a number of advantages of similar products home and abroad, stable performance and easy to operate, it is the first choice for metrological service and laboratory.
Main specifications and technical parameters
|
Type |
50W&500W |
|
Meet the standards |
IEC60695,GB5169,UL94,UL498,UL1363,UL498A and UL817 |
|
Power |
220V,50HZ or 110V, 60Hz |
|
Operating system |
Mitsubishi PLC control,Weinview 7 inch color touch screen operation |
|
Burner |
Diameter 9.5mm ± 0.5mm,length 100mm,Imported products,conform to ASTM5025 |
|
Burning angle |
0°,20°,45°adjustable |
|
Flame height |
20mm~125mm±1mm adjustable |
|
Timing device |
9999X0.1s can be preset |
|
Thermocouple |
Φ0.5mm Omega K-type thermocouple |
|
Thermometry distance |
10±1mm/55±1mm |
|
Temperature measurement |
MAX 1100°C |
|
Gas flow |
Using imported flowmeter,105 ± 10 ml/min and 965±30ml/min adjustable,precision 1% |
|
Height of water column |
Using imported U-tube, the height difference is less than 10mm |
|
Checking time |
44±2S/54±2S |
|
Thermometry copper head |
Ф5.5mm,1.76± 0.01 g;Ф9mm±0.01mm10 ± 0 .05 g,Cu-ETP purity:99.96% |
|
Gas category |
Methane |
|
Box volume |
More than 1 cube,black matte background with exhaust fan |
|
|
50W 500W Mitsubishi PLC Plastic Vertical Horizontal Flammability Tester UL94 Fire Chamber Images |